  an economical means of transferring power double-throw safety switch industrial light commercial residential agricultural
double-throw safety switches eatons double-throw safety switches are used to transfer service from a normal power source to an alternate source, or to switch from one load circuit to another. the manually operated double-throw safety switch provides an economical means of transferring power. eaton offers a full line of general-duty and heavy-duty double-throw safety switches. general-duty eatons general-duty double- throw safety switches are commonly applied in emergency power or generator applications to reduce or eliminate the costly impact of power loss from the typical source in residential, agricultural and light commer - cial markets. all general-duty double-throw safety switches are non-fusible and are available up to 400a. a standby generator connected to a residential wiring system must be installed according to the national electrical code. ? a double-throw switch must be installed to isolate and discon - nect wiring from normal utility lines so that generator-produced electricity is not back-fed onto normal utility lines. whether normal electrical service is disrupted by severe weather conditions, accidents or other issues, an eaton general- duty double-throw safety switch is a critical component in your standby generator applications. heavy-duty eatons heavy-duty double- throw safety switches are designed for commercial and industrial applications. fusible switches are available through 600a, while non-fusible switches are manufactured up to 800a. the wiring configuration from the factory allows a single load to be supplied by a normal or alternate source; however, where necessary, the wiring can be field modified to allow two loads to be alternately supplied by a single power source. heavy-duty double-throw safety switches are designed to accommodate a wide range of accessories that can be factory or field installed. customized solutions, including key inter - locks, viewing windows and receptacles, are also available through eatons switching device flex center. double-throw general-duty non-fusible safety switches dt224urk-nps quick-make, quick-break design, 200a, 240v. double-throw, 240 vac general-duty, non-fusible compact design specifcations ? 30C100a ? suitable for service entrance use with neutral kit installed ? suitable for use as a manu - ally operated switch per 2005 nec ? article 702 ? ul ? listed file no. e5239 features ? palm-fitting, visible red handle ? tri-lingual nameplate ? nema ? 3r enclosure with side opening door ? visible, embossed on-off indication ? concentric knockouts on bottom endwall and sides ? lockable door hasp ? lockable handle ? three-point mounting ? factory-installed neutral (optional catalog numbers are available without a neutral) ? terminals suitable for 60o or 75oc al or cu wire ? rounded shroud ? mechanical door interlock to prevent easy access when the switch is in the on position ? suitable for use on a circuit capable of delivering not more than 10,000 rms symmetrical amperes ? compact size double-throw, 240 vac general-duty, non-fusible, quick-make, quick-break design specifcations ? 30C400a ? horsepower rated ? suitable for service entrance use with neutral kit installed ? suitable for use as a manually operated switch per 2005 nec article 702 ? ul listed file no. e5239 ? quick-make, quick-break operating mechanism features ? palm-fitting, visible red handle ? tri-lingual nameplate ? nema 3r enclosure with side opening door ? visible, embossed red on-off indication ? tangential knockouts (30C100a) on bottom end - wall; concentric knockouts on higher ratings, and sides and rear of 30C100a ? lockable door hasp ? lockable handle ? factory-installed neutral (optional catalog numbers are available without a neutral) ? three-point mounting (30C100a) ? four-point mounting (200C400a) ? terminals suitable for 60o or 75oc al or cu wire on 30C100a; 75oc al or cu wire on higher ratings ? rounded shroud ? door cannot be opened with the switch on. switch cannot be turned on with door open (without operating interlock defeater) ? suitable for use on a circuit capable of delivering not more than 100,000 rms symmetrical amperes when protected by class r or j fuses (30C200a); r, t or j fuses (400a). short-circuit rating is 10,000 rms symmetrical amperes when protected by any other overcurrent protective device ? double-break visible rotary blades; quick-make, quick- break operation double-throw compact design ampere rating main and standby nema 3r enclosure rainproof catalog number non-fusible two-pole240 vac 30 60 100 dt221urh dt222urh dt223urh non-fusible two-pole, three-wire240 vacsolid neutral 30 60 100 dt221urh-n dt222urh-n dt223urh-n double-throw quick-make, quick-break design ampere rating main and standby maximum horsepower ratings nema 3r enclosure rainproof single-phase 240 vac 250 vdc catalog number non-fusible two-pole240 vac250 vdc 30 60 100 200 400 3 10 20 15 5 10 20 40 50 dt221urkps dt222urkps dt223urkps dt224urkps dt225urkps non-fusible two-pole, three-wire240 vac250 vdcsolid neutral 30 60 100 200 400 3 10 20 15 5 10 20 40 50 dt221urk-nps dt222urk-nps dt223urk-nps dt224urk-nps dt225urk-nps on of f on on of f on s / n non-fusible two -pole two sources or two loads on of f on on of f on s / n non-fusible two -pole with neutral two sources or two loads dt223urh-n compact design, 100a, 240v on of f on on of f on s / n non-fusible two -pole two sources or two loads on of f on on of f on s / n non-fusible two -pole with neutral two sources or two loads 2 eaton corporation double-throw safety switch 3 eaton corporation double-throw safety switch
double-throw heavy-duty non-fusible safety switches double-throw heavy-duty fusible safety switches double-throw 240 and 600 vac heavy-duty, fusible specifcations ? 30C600a ? horsepower rated ? suitable for service entrance use with neutral or ground lug kit installed ? suitable for use as a manually operated switch per 2005 nec article 702 ? ul listed file no e5239 features ? palm-fitting, visible red handle ? tri-lingual nameplate ? side opening doors on all enclosures ? clear line shield to prevent accidental contact with energized parts; probe holes enable line side testing without removing the shield ? wiring configuration from factory allows a single load to be supplied by a normal or alternate source; can be modified to allow two loads to be alternately supplied by a single power source ? visible, embossed red on-off indication ? tangential knockouts (30C100a) on top and bottom endwall (bottom only on nema 3r); concentric knock - outs on higher ratings, and sides and rear of 30C100a ? lockable door hasp ? lockable handle ? three-point mounting (30C100a) ? four-point mounting (200C600a) ? terminals suitable for 60o or 75oc al or cu wire on 30C100a; 75oc al or cu wire on higher ratings ? rounded shroud ? full range of accessories ? door cannot be opened with the switch on. switch cannot be turned on with door open (without oper - ating interlock defeater) ? suitable for use on a circuit capable of delivering not more than 100,000 rms sym - metrical amperes when pro - tected by class r or j fuses (30C200a); r, t or j fuses (400C600a). short-circuit rat - ing is 10,000 rms symmetrical amperes when protected by any other overcurrent protec - tive device ? double-break visible rotary blades; quick-make, quick- break operation double-throw 240 and 600 vac heavy-duty, non-fusible specifcations ? 30C800a ? horsepower rated ? suitable for service entrance use with neutral or ground lug kit installed ? suitable for use as a manually operated switch per 2005 nec article 702 ? ul listed file no. e5239 features ? palm-fitting, visible red handle ? tri-lingual nameplate ? side opening doors on all enclosures ? visible, embossed red on-off indication ? tangential knockouts (30C100a) on top and bot - tom endwall (bottom only on nema 3r); concentric knock - outs on higher ratings, and sides and rear of 30C100a ? lockable door hasp ? lockable handle ? three-point mounting (30C100a) ? four-point mounting (200C800a) ? terminals suitable for 60o or 75oc al or cu wire on 30C100a; 75oc al or cu wire on higher ratings ? rounded shroud ? full range of accessories ? door cannot be opened with the switch on; switch cannot be turned on with door open (without operating interlock defeater) ? suitable for use on a circuit capable of delivering not more than 100,000 rms symmetrical amperes when protected by class r or j fuses (30C200a); r, t or j fuses (400C800a). short-circuit rating is 10,000 rms symmetrical amperes when protected by any other overcurrent protective device ? double-break visible rotary blades; quick-make, quick- break operation dt363fgk double-throw heavy-duty fusible safety switch, 100a, 600v dt363urk double-throw heavy-duty non- fusible safety switch, 100a, 600v double-throw 240 vac heavy-duty, fusible ampere rating main and standby fuse class provision maximum horsepower ratings with time-delay fuses nema 1 enclosure indoor nema 3r enclosure rainproof single-phase 240 vac three-phase 240 vac 250 vdc catalog number catalog number two-pole240 vac250 vdc 200 h 15 40 dt224fgk dt224frk three-pole240 vac250 vdc 30 60 100 200 400 600 1 h h h h h t 3 10 15 15 7-1/2 15 30 60 125 50 5 10 20 40 50 50 dt321fgk dt322fgk dt323fgk dt324fgk dt325fgk dt326fgk dt321frk dt322frk dt323frk dt324frk dt325frk dt326frk a only available for use with fast-acting fuses. standard hp rating is shown. double-throw 600 vac heavy-duty, fusible ampere rating main and standby fuse class provision maximum horsepower ratings with time-delay fuses nema 1 enclosure indoor nema 3r enclosure rainproof nema 4x enclosure, corrosion-resistant stainless steel single-phase three-phase 480 vac 600 vac 480 vac 600 vac 250 vdc catalog number catalog number catalog number three-pole600 vac250 vdc 30 60 100 200 400 h h h h t 7-1/2 20 30 50 10 25 40 50 15 30 60 125 250 20 50 75 150 350 40 50 dt361fgk dt362fgk dt363fgk dt364fgk dt365fgk dt363frk dt364frk dt365frk dt361fwk dt362fwk dt363fwk dt364fwk dt365fwk on on off fusible two -pole two sources on on off fusible two -pole two loads on on off fusible three -pole two sources on on off fusible three -pole two loads fusible three -pole two sources on on off fusible three -pole two loads double-throw 240 vac heavy-duty, non-fusible ampere rating main and standby maximum horsepower ratings nema 1 enclosure indoor nema 3r enclosure rainproof single- phase three-phase 240 vac 240 vac 250 vdc catalog number catalog number non-fusible two-pole240 vac250 vdc 30 60 100 200 400 600 3 10 20 15 5 10 20 40 50 dt221ugk dt222ugk dt223ugk dt224ugk dt225ugk dt226ugk dt224urk dt225urk non fusible three-pole240 vac250 vdc 30 60 100 200 400 600 800 800 3 10 20 15 10 20 40 60 125 125 125 125 5 10 20 40 50 50 50 50 dt321ugk dt322ugk dt323ugk dt324ugk dt325ugk dt326ugk dt327ugk 1 2 dt327ugk-n dt323urk dt324urk dt325urk a warning: switch is not approved for service entrance. b field-installable neutral kit is not available. if a neutral is required, order the catalog number shown in the table with n suffix. on of f on non-fusible 2-pole two sources or two loads on o f f on non-fusible 3-pole two sources or two loads on of f on s / n non-fusible 3-pole with neutral two sources or two loads 4 eaton corporation double-throw safety switch 5 eaton corporation double-throw safety switch
double-throw heavy-duty switching neutral safety switches double-throw heavy-duty non-fusible safety switches double-throw switching neutral safety switch (upper switch base assembly is shown) double-throw 600 vac heavy-duty, non-fusible ampere rating main and standby maximum horsepower ratings nema 1 enclosure indoor nema 3r enclosure rainproof nema 12 enclosure industrial, dust-tight nema 4x enclosure, corrosion-resistant, stainless steel single-phase three-phase 480 vac 600 vac 480 vac 600 vac 480 vdc catalog number catalog number catalog number catalog number two-pole600 vac250 vdc 30 60 100 200 400 600 7-1/2 20 40 50 10 25 50 50 5 10 20 40 50 50 dt261ugk dt262ugk dt263ugk dt264ugk 1 dt265ugk dt266ugk dt264urk 1 DT265URK dt266urk three-pole600 vac250 vdc 30 60 100 200 400 600 800 800 7-1/2 20 40 50 10 25 50 50 20 50 75 125 250 250 250 250 30 60 100 150 350 350 350 350 5 10 20 40 50 50 50 50 dt361ugk dt362ugk dt363ugk dt364ugk dt365ugk dt366ugk dt367ugk 2 3 dt367ugk-n dt361urk dt362urk dt363urk dt364urk dt365urk dt366urk dt367urk 2 3 dt367urk-n dt361udk 4 dt362udk 4 dt363udk 4 dt364udk 4 dt365udk 4 5 4 4 4 dt361uwk dt362uwk dt363uwk dt364uwk dt365uwk four-pole600 vac250 vdc 2 30 60 100 200 400 600 800 7-1/2 20 40 10 25 50 50 20 50 75 125 250 250 250 30 60 100 150 350 350 350 5 10 20 40 50 50 50 dt464ugk dt465ugk dt466ugk dt467ugk dt461urk dt462urk dt463urk dt464urk dt465urk dt466urk dt467urk six-pole600 vac250 vdc 2 30 60 100 7-1/2 20 40 10 25 50 15 50 75 30 60 100 5 10 20 dt661urk dt662urk dt663urk a rated 600 vdc, 50 hp in addition to ratings shown in table. b warning: switch is not approved for service entrance. c field-installable neutral kit is not available. if a neutral is required, order the catalog number shown in the table with n suffix. d nema 12 enclosures (30C800a) can be field modified to meet nema 3r rainproof requirements when a factory-provided drain hole is opened. e also available in 240 vac, catalog number dt325udk . on of f on non-fusible two -pole two sources or two loads on o f f on non-fusible four -pole two sources or two loads bonding kit schematic single-phase applications requiring a neutral pole bonding kit bonding kit schematic three-phase applications requiring a neutral pole bonding kit otes s n nec 702 application, separately derived system and service equipment. two sources with switched neutral, generator is a separately derived system. proper installation is governed by interpretation of the nec, applicable local codes and local utility requirements. applicable sections of these codes and requirements should be referenced prior to installation. on o f f on non-fusible three -pole two sources or two loads on of f on s / n non-fusible three -pole with neutral two sources or two loads on o f f on non-fusible six -pole two sources or two loads double-throw safety switches applied in emergency power or generator applications may require a switched neutral in lieu of a solid neutral. if the neutral of the generator is bonded to a grounding system at the generator, then a separately derived system (reference nec 250-20[d] and exhibit 250.7) has been created and a switched neutral in the double-throw safety switch is required. the switching neutral is required to avoid the potential for backfeeding of the power that might occur if the safety switch neutral is also bonded. if the generator neutral is brought to the service where it is bonded and grounded, then a non-separately derived system has been created and a solid neutral must be used in the double-throw safety switch. most double-throw safety switches in todays market are provided with solid neutrals and are not ul listed for switching neutral application. the market, some utilities and local codes are requiring the ability to break or switch the neutral on three- and four-pole double-throw switches with a ul listing for that capability. three-pole switches are used for single-phase switching neutral applications, while four-pole switches are used for three-phase switching neutral applications. in many cases, three- and four-pole double-throw safety switches are being installed in the field with the left-most pole being used as the switching neutral, but the switch is not ul listed for that application. eaton non-fusible three-pole and four-pole double-throw safety switches 30C800a are ul listed for switching neutral application with the proper installation of the applicable switching neutral bonding kit shown in the accessories section of this bro - chure. each bonding kit comes with applicable materials, hard - ware, instruction sheet and adhesive-backed wiring schematic. the bonding kits can only be used on non-fusible double-throw safety switches. when a bond - ing kit is applied to a three-pole switch, the switch becomes a single-phase switch with single- phase horsepower ratings. a double-throw safety switch with the appropriate bonding kit installed is suitable for service entrance use. typically, a four-pole double-throw safety switch is not suitable for service entrance use; however, with the appropriate bonding kit installed, the four- pole switch is suitable for service entrance use as noted on the device publication of the product. switching neutral bonding kits can also be factory installed by eatons unique switching device flex center. see the end of this brochure for additional information on the flex center. 6 eaton corporation double-throw safety switch 7 eaton corporation double-throw safety switch
accessories, hubs and standard lug capacities description catalog number neutral kits/ground kits 1 30C100a 200a 400a non-fusible 600a non-fusible 400C600a fusible dt100nk dt200nk dt400nk dt600nk ds800nk ground lug kits 1 30C100a 2 200a 400C800a ds100gk ds200gk ds468gk switching neutral bonding kits 3 30C100a, three-pole, four-pole non-fusible 200a, three-pole, four-pole non-fusible 400a, three-pole, four-pole non-fusible 600a, three-pole, four-pole non-fusible 800a, three-pole, four-pole non-fusible dt100bk dt200bk dt400bk dt600bk dt800bk control pole kit 1 30C800a ds16cp auxiliary contact kits 1 1no/1nc 2no/2nc ds200ek1 ds200ek2 copper lug kits 1 30C60a 100a ds16cl ds36cl j fuse adapter kits 4 60a 400a 600v ds26jk dt400jk r fuse adapter kits 4 30a, 240v 30a, 600v; 60a, 240v 60a, 600v 100a, 240C600v 200a, 240C600v 400a, 240v ds12fk ds16fk ds26fk ds36fk ds46fk ds56fk lubricating grease for safety switch blades and contacts each kit contains three 30 cc tubes of lubricating grease. dslubekit a for heavy-duty and general-duty quick-make, quick-break. b ground bar kit is not listed on device publications. c for heavy-duty non-fusible. d for heavy-duty fusible. plate type hubs for nema 3r enclosures (up to 200a) group 1 general-duty, heavy-duty, double-throw through 100a group 2 general-duty, heavy-duty, double-throw through 200a conduit size in inches (mm) catalog number conduit size in inches (mm) catalog number 0.75 (19.1) 1.00 (25.4) 1.25 (31.8) 1.50 (38.1) 2.00 (50.8) ds075h1 ds100h1 ds125h1 ds150h1 ds200h1 2.00 (50.8) 2.50 (63.5) 3.00 (76.2) ds200h2 ds250h2 ds300h2 myers type hubs nema 3r (400a and above) nema 4x (stainless steel) and 12 conduit size in inches (mm) catalog number 0.50 (12.7) 0.75 (19.1) 1.00 (25.4) 1.25 (31.8) 1.50 (38.1) 2.00 (50.8) 2.50 (63.5) 3.00 (76.2) 3.50 (88.9) 4.00 (101.6) 5.00 (127.0) ds050mh ds075mh ds100mh ds125mh ds150mh ds200mh ds250mh ds300mh ds350mh ds400mh ds500mh description minimum wire size maximum wire size wire type 30a 60a 100a 200a 400a 600a fusible 600a non-fusible 800a #14 #14 #14 #6 (2) #1/0 (1) #1/0 (1) #2 (1) #1/0 (2) #250 (3) #250 #2 #2 #1/0 250 kcmil (2) 300 kcmil (1) 750 kcmil (1) 600 kcmil (1) 750 kcmil (2) 500 kcmil (3) 500 kcmil cu/al cu/al cu/al cu/al cu/al cu/al cu/al cu/al cu/al cu/al copper-bodied lugs 30a 60a 100a 200a 400a 600a #14 #14 #6 #6 #1/0 (2) #1/0 #6 #4 #1/0 250 kcmil 500 kcmil (2) 500 kcmil cu cu cu cu cu cu 1. dt200nk 200a neutral/ground kit 2. ds250h2 plate type hub 3. ds26fk 60a 600v r fuse adapter kit 4. dt100bk 100a switching neutral bonding kit 5. ds468gk 400C800a ground lug kit 6. ds050mh myers hub 7. ds200ek1 auxiliary contact kit 1no/1nc 8. ds16cp control pole kit 9. ds26jk 60a j fuse adapter kit 10. ds16cl 30C60a copper lug kit 1 5 9 2 6 10 3 7 4 8 accessories neutral, ground lug, control pole and auxiliary contact kits contain materials for one switch base. copper lug, 60a j fuse and r fuse kits contain materials for one three-pole switch base. switching neu - tral bonding and 400a j fuse kit contents are for one complete dou - ble-throw switch. applicable accessories for a specific safety switch can also be found on the inside door publication of the switch hubs catalog number ds900ap adapter kit permits installation of group 1 hubs on 200a double-throw switches. standard lug capacities although certain lug capacities are larger than required, only mini - mum wire bending space is provided per the requirements noted in nec tables 373-6 (a) and (b) for respective ampere ratings. 8 eaton corporation double-throw safety switch 9 eaton corporation double-throw safety switch
dimensions and weights w c l h d d2 w c l h d d2 w h d d2 double-throw general-duty, non-fusible, 240v, two-pole solid neutral, compact design ampere rating nema 3r dimensions in inches (mm) weight lbs (kg) height (h) width (w) depth (d) depth (d2) 30 60 100 14.69 (373.1) 14.69 (373.1) 14.69 (373.1) 9.63 (244.6) 9.63 (244.6) 9.63 (244.6) 10.81 (274.6) 10.81 (274.6) 10.81 (274.6) 5.23 (132.8) 5.23 (132.8) 5.23 (132.8) 12 (5.4) 12 (5.4) 12 (5.4) double-throw heavy-duty, non-fusible, 240v and 600v, three-pole ampere rating nema 1, 3r dimensions in inches (mm) weight lbs (kg) nema 12, 4x stainless steel dimensions in inches (mm) weight lbs (kg) width (w) height (h) depth (d) depth (d2) width (w) height (h) depth (d) depth (d2) 30 11.94 (303.3) 24.63 (625.6) 9.88 (251.0) 5.38 (136.7) 34 (15.4) 12.00 (304.8) 25.88 (657.4) 10.25 (260.4) 5.50 (139.7) 60 (27.2) 60 11.94 (303.3) 24.63 (625.6) 9.88 (251.0) 5.38 (136.7) 34 (15.4) 12.00 (304.8) 25.88 (657.4) 10.25 (260.4) 5.50 (139.7) 60 (27.2) 100 11.94 (303.3) 24.63 (625.6) 9.88 (251.0) 5.38 (136.7) 34 (15.4) 12.00 (304.8) 25.88 (657.4) 10.25 (260.4) 5.50 (139.7) 60 (27.2) 200 19.56 (496.8) 37.38 (949.5) 11.25 (285.8) 6.10 (154.9) 80 (36.3) 19.50 (495.3) 41.00 (1041.4) 11.63 (295.4) 6.48 (164.6) 105 (47.6) 400 23.13 (587.5) 53.81 (1366.8) 12.50 (317.5) 7.25 (184.2) 140 (63.6) 23.00 (584.2) 57.50 (1460.5) 12.50 (317.5) 7.25 (184.2) 185 (83.9) 600 24.13 (612.9) 63.31 (1608.1) 14.13 (358.9) 8.88 (225.6) 175 (79.4) 800 24.13 (612.9) 63.31 (1608.1) 14.13 (358.9) 8.88 (225.6) 175 (79.4) double-throw general-duty, non-fusible, 240v, two-pole solid neutral, quick-make, quick-break design ampere rating nema 3r dimensions in inches (mm) weight lbs (kg) height (h) width (w) depth (d) depth (d2) 30 60 100 24.63 (625.6) 24.63 (625.6) 24.63 (625.6) 11.94 (303.3) 11.94 (303.3) 11.94 (303.3) 9.88 (251.0) 9.88 (251.0) 9.88 (251.0) 5.38 (136.7) 5.38 (136.7) 5.38 (136.7) 34 (15.4) 34 (15.4) 34 (15.4) 200 400 37.38 (949.5) 53.81 (1366.8) 19.56 (496.8) 23.13 (587.5) 11.25 (285.8) 12.50 (317.5) 6.10 (154.9) 8.88 (225.6) 80 (36.3) 140 (63.6) 1. general-duty nema 3r 30C400a 2. heavy-duty nema 1, 3r 30C800a 3. heavy-duty nema 12, 4x 30C400a note contact your eaton sales office for outline drawings and mounting dimensions. double-throw heavy-duty, fusible, 240v and 600v, three-pole ampere rating nema 1, 3r dimensions in inches (mm) weight lbs (kg) nema 12, 4x stainless steel dimensions in inches (mm) width (w) height (h) depth (d) depth (d2) width (w) height (h) depth (d) depth (d2) weight lbs (kg) 30 11.94 (303.3) 36.63 (930.4) 9.88 (251.0) 5.38 (136.7) 44 (20.0) 12.00 (304.8) 39.81 (1011.2) 10.25 (260.4) 5.50 (139.7) 45 (20.4) 60 11.94 (303.3) 36.63 (930.4) 9.88 (251.0) 5.38 (136.7) 44 (20.0) 12.00 (304.8) 39.81 (1011.2) 10.25 (260.4) 5.50 (139.7) 45 (20.4) 100 11.94 (303.3) 36.63 (930.4) 9.88 (251.0) 5.38 (136.7) 44 (20.0) 12.00 (304.8) 39.81 (1011.2) 10.25 (260.4) 5.50 (139.7) 45 (20.4) 200 19.56 (496.8) 50.88 (1292.4) 11.25 (285.8) 6.10 (154.9) 95 (43.1) 19.56 (496.8) 55.63 (1413.0) 11.63 (295.4) 6.46 (164.1) 100 (45.4) 400 25.38 (644.7) 74.75 (1898.7) 14.13 (358.9) 8.88 (225.6) 230 (104.3) 25.38 (644.7) 74.75 (1898.7) 14.13 (358.9) 8.92 (226.6) 260 (117.9) 600 27.44 (697.0) 86.13 (2187.7) 14.13 (358.9) 8.88 (225.6) 320 (145.1) 1 2 3 non-fusible switches the ul listed short-circuit ratings for eaton non-fusible switches are based on the switches being properly pro - tected by overcurrent protective devices. for applications that require a ul listed short-circuit rating of 10,000 rms symmetrical amperes or less, an eaton non- fusible switch must be properly protected by any overcurrent protective device rated no greater than the ampere rating of the switch. for applications that require a ul listed short-circuit rating of greater than 10,000 rms symmetrical amperes, an eaton non-fusible switch must be properly protected by the appropriate class and size fusing noted on the switch publication. otherwise, this non-fusible switch must be replaced with an eaton fusible switch that uses the appropriate fusing required. safety switch short circuit rat - ings are applicable to ac only. safety switch i 2 t and ip values are identical to ul maximum acceptable i 2 t and ip values for the corresponding class fuse. renewal parts replacement parts for a specific catalog number are shown on the inside door label (publica - tion) of the switch. switch bases, fuse bases, line shields (fusible switches) and operating handles (400a and above) are typically available as applicable. for additional information, refer to renewal parts catalog rp00801001e. flex center our cleveland, tn, switching devices flex center is a solu- tions center that designs and modifies safety switches, enclosed circuit breakers and rotary disconnects for unique customer needs that are not met by standard products. the flex center is a one-of-a-kind operation that is capable of solving our customers issues, while our competition is content to offer their customers only catalog items. the flex center staff has over 120 years of design, manufac- turing and industry experience, and has been providing solutions to our customers since 1998. while you may think that your power switching needs are unlike any other, chances are, the flex center staff has already been there, done that. for further information on our customized solutions for harsh environments, safety and convenience, please refer to our flex center brochure sa00801002e or contact the flex center at 1-888-329-9272. short-circuit ratings using class r, t or j fusing where applicable class h fuse clips supplied as standard for 30C600a except class t for 400a at 600v, and 600a at 240v. rated at 10,000 rms symmetrical when using class h fuses. not applicable to the compact design. the compact design is suitable for use on a circuit capable of delivering not more than 10,000 rms symmetrical amperes. ampere rating voltage ratings type 1 type 3r type 12 type 4x 30 60 100 200 400 600 800 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 100k at 600 short-circuit ratings 10 eaton corporation double-throw safety switch 11 eaton corporation double-throw safety switch
eatons electrical sector is a global leader in power distribution, power quality, control and automation, and monitoring products. when combined with eatons full-scale engineering services, these products provide customer- driven powerchain e solutions to serve the power system needs of the data center, industrial, institutional, public sector, utility, commercial, residential, it, mission critical, alternative energy and oem markets worldwide. powerchain solutions help enterprises achieve sustainable and competitive advantages through proactive management of the power system as a strategic, integrated asset throughout its life cycle, resulting in enhanced safety, greater reliability and energy efficiency. for more information, visit www.eaton.com/electrical. eaton corporation electrical sector 1111 superior ave. cleveland, oh 44114 united states 877-etn-care (877-386-2273) eaton.com ? 2010 eaton corporation all rights reserved printed in usa publication no. br00801002e / z10432 november 2010 powerchain management is a registered trademark of eaton corporation. all other trademarks are property of their respective owners.


▲Up To Search▲   

 
Price & Availability of DT265URK

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X